国产在视频精品视频_熟妇人妻一区二区三区四区 _日韩精品一区二区三区在线观看 _国产精品日韩在线观看一区二区 _欧美成人片一区二区三区

您好!歡迎訪問上海艾研生物科技有限公司網站!
全國服務咨詢熱線:

13918425787

當前位置:首頁 > 產品中心 > 美國伯樂 > 美國伯樂電泳系統 > TC20全自動細胞計數儀

TC20全自動細胞計數儀

簡要描述:TC20全自動細胞計數儀

  • 產品型號:
  • 廠商性質:代理商
  • 更新時間:2024-08-22
  • 訪  問  量:2380

詳細介紹

品牌Bio-Rad/伯樂

TC20全自動細胞計數儀

TC20全自動細胞計數儀

The TC20 automated cell counter counts mammalian cells in one simple step using its innovative auto-focus technology and sophisticated cell counting algorithm to produce accurate cell counts in less than 30 seconds. Upon insertion of a counting slide, the TC20 cell counter rapidly provides a total cell count (with or without trypan blue staining) and assesses cell viability via trypan blue exclusion.

Key Features and Benefits

·         Compatible with a broad range of cell sizes and types — counts cell lines, primary cells (from tissue or blood), and stem cells

·         Innovative auto-focus technology — removes the variation associated with manual focusing and leads to precise cell counts in 30 seconds

·         Cell size gates — user selects a population of interest in complex samples, such as primary cells, or lets the cell counting algorithm do all the work

·         Cell viability — analyzes cells accuray using multifocal plane analysis

·         Easy to archive and analyze — stores up to 100 counts in the onboard memory for access any time, or use the optional TC20 data analyzer software on your PC to further analyze exported cell images

Getting all the data you need about your cell cultures is fast and easy; the TC20 cell counter and disposable counting slides eliminate the need for tedious setup, cleaning, or maintenance. The TC20 cell counter is simple and intuitive to use 

Get Accurate and Reproducible Results

The TC20 automated cell counter uses microscopy with auto-focus that analyzes multiple focal planes to identify the best plane. Without requiring any user input, the sophisticated cell counting algorithm uses the image acquired from the best focal plane to identify cells and exclude debris, thereby calculating the total cell count. The auto-focus leads to highly reproducible cell counts with reduced user-to-user variability compared to a hemocytometer and cell counters with manual focus. Using auto-focus instead of subjective manual focusing is especially important when assessing cell viability because an incorrectly selected focal plane will lead to inaccurate results.

Unlike cell counters based on electrical impedance (Coulter principle), the TC20 image-based analysis allows the user to view the cells in real time, providing visual proof that the TC20 cell counter has correctly identified cells.

The TC20 automated cell counter provides accuracy comparable to results obtained with a hemocytometer. It can count cells with a 6–50 μm cell diameter and within a broad concentration range of 5 x 104–1 x 107cells/ml, which eliminates the need to dilute cells, thus reducing errors associated with sample dilutions prior to counting.

The counter uses disposable counting slides with a patent-pending design that ensures even distribution of cells throughout the counting chamber, regardless of the user's pipetting style, leading to accurate and consistent cell counts.

For complex samples composed of multiple cell populations, such as primary cells, users can adjust the cell size gates to define the population of interest that will be counted. When counting multiple sample replicates, the TC20 cell counter can save the position of the cell size gates and apply them to subsequent counts.

 

Cell Viability

The TC20 cell counter uses multifocal plane analysis to assess cell viability. The conventional method of analyzing viability using a single focal plane can lead to inaccurate conclusions because light scattering and the alignment of cells at different heights in a counting chamber can change the appearance of cells — live cells may appear to be dead and vice versa. To determine if cells are viable, the TC20 counter analyzes each cell using images acquired from multiple focal planes during the focusing step.

Minimize Your Sample Preparation

The broad concentration range of the TC20 cell counter eliminates the need to dilute cells prior to counting, reducing the errors associated with sample dilutions that may be necessary when counting cells by other methods. The counting algorithm discriminates and counts individual cells within clusters of up to five cells, providing accurate counts without the need to extensively declump cells prior to loading.

 

 

Counting time, sec

30

Cell concentration range, cells/ml

5 x 104–1 x 107

Optimal cell concentration range, cells/ml

1 x 105–5 x 106

Cell diameter range, µm

6–50

Sample volume, µl

10

Data storage, counts

100

Data export

Via USB flash drive

Printer connectivity

Yes

Dilution calculator

Yes

Image of cells available

Yes

Dimensions (W x D x H), cm (in)

19 x 15 x 25.4 (7.5 x 6 x 10)

Weight without the external power supply, kg (lb)

2.2 (4.8)

產品咨詢

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7
掃一掃,關注微信
地址:上海市浦東新區錦繡東路412弄28號 傳真:86-021-61924370
©2024 上海艾研生物科技有限公司 版權所有 All Rights Reserved.  備案號:滬ICP備16048870號-1